The Sewage Guy Logo

Category: Blog

Advice for repairing a leaking F-line tank

The F-line tank is extremely popular due to it's shallow design and pump sump which maximises the use of water within the tank. However, upon installing the tank it is absolutely vital to ensure that the sump does not prop up the main floor of the tank. My advice for installing these tanks is always […]

Read More
What is the Solido "Error Accu"?

The Solido smart control panel has 2 x AA rechargeable batteries in to store settings in the event of power failure. Very occasionally these may need replacing and should be carried out by your service company to ensure the correct ones are used and the panel is opened without damaging anything. Do not install normal […]

Read More
Fluido FS20 Errors

The FS20 control panel is the latest version of the control panel for the Rewatec Fluido. there are a number of errors it can display as follows: There is also a red warning light to indicate a fault has arisen, and an amber warning light to suggest the Fluido needs an annual maintenance Contact me […]

Read More
Fluido F-control Errors

The Fluido F-control has a built in alarm system to monitor the Fluido sewage treatment plant and can display a number of errors. It also has a service light to remind you when the system requires an annual service. Typical Errors that can occur are: The F-control can suffer from corrosion if installed in a […]

Read More
Fluido BSP Breakdown alarm

the Mono Fluido BSP Breakdown alarm is a fault that happens often when the the control panel registers the current consumption of the BSP pump to be 0. What are the possible causes of the BSP Breakdown alarm? The alarm can be caused by the pump breaking, a damaged cable or even a fault in […]

Read More
Fluido BSP Blockage alarm

This alarm happens when the current (amps) increases on the BSP pump in the Fluido. It is normally easy to rectify, however it should be done by a professional as it involves stripping down the pump and returning all the components to the original design. What is the BSP pump? The BSP Pump is the […]

Read More
Fluido KWP Breakdown Alarm

The advanced alarm system on the Fluido will warn you if there is a KWP Breakdown, however the fault is sometimes not always the pump. What is this alarm? Specifically this alarm is a warning that no current is being consumed by the KWP. Why has this alarm happened? The alarm will happen if the […]

Read More
Fluido KWP Blockage alarm

The Fluido KWP blockage alarm isn't common, but vital to fix if it happens. This article describes the problem and why it has happened. What is the KWP? KWP is the acronym used in the Fluido for the Clearwater pump. Why has the alarm sounded? The alarm sounds when the current consumption of the pump […]

Read More
Fluido High Level Alarm

The Fluido has a comprehensive alarm function, warning you if there is a problem. The High level alarm throws a lot of service companies because it is a little more complex than a normal high level alarm. What is the alarm? The high level alarm on the Fluido works slightly differently than a normal high […]

Read More
Fluido BEL Blockage Alarm

What does the BEL Blockage alarm on a Fluido mean? this short article will explain what it is and how important it is to resolve. Why has this alarm happened? The BEL Blockage Alarm happens when the control panel notices the current has increased beyond normal working parameters. Why might the current increase? Normally a […]

Read More
©2026 The Sewage Guy